Pzem-017 Software Download !full!
For users who want a quick, "plug-and-play" visual experience without heavy coding, several web-based options are available:
Search the for PZEM017 (by @olehs). This library allows you to read energy data directly onto an LCD or SD card logger without a PC.
: You must choose your specific shunt rating (e.g., 100A) in the software settings. If the wrong shunt size is selected, current and power readings will be incorrect.
: Open-source libraries exist for Arduino, but some users have uploaded versions of the PC interface software there. Alternative: Web-Based Interface pzem-017 software download
: Change the Modbus device address if you plan to chain multiple PZEM modules on a single RS485 bus. 🔍 Troubleshooting Common Connection Issues
For industrial or custom setups, Python’s minimalmodbus or pymodbus libraries can read the PZEM-017. Node-RED flows are also widely available on GitHub.
uart: tx_pin: GPIO15 rx_pin: GPIO13 baud_rate: 9600 stop_bits: 2 For users who want a quick, "plug-and-play" visual
: Alternatively, you can integrate the PZEM-017 directly into Home Assistant using its built-in Modbus integration if you use an RS485 to TCP adapter like the USR-DR302.
A simpler, single‑file Python interface ( pzem.py ) that works with both AC and DC PZEM modules. It uses the pymodbus library instead of minimalmodbus and is a lightweight choice for Raspberry Pi applications.
| Problem | Likely Cause | Solution | |---------|--------------|----------| | No data read | Wrong COM port or baud rate | Verify in Device Manager / ls /dev/tty* that the adapter appears; ensure software is set to | | Slave address mismatch | Device address changed from default | Use change_settings.py or official software to scan for devices; common addresses are 1, 2, or 247 | | Incorrect readings | Current range not set to match shunt | Use change_settings.py option 3 to set the shunt’s full‑scale value (50,100,200,300 A) | | Communication stops after a few reads | Poor power supply to PZEM‑017 | Provide a stable 5 V from an independent USB charger, not from the PC’s USB port | | Device resets energy at midnight | Normal automatic daily reset | The meter automatically resets daily energy to zero at midnight; to reset manually, write the reset command via Modbus | | “No response from slave” errors | RS‑485 termination or wiring issue | Check A/B line polarity; add a 120 Ω terminating resistor at the end of the RS‑485 bus if multiple devices are daisy‑chained | If the wrong shunt size is selected, current
Connect the PZEM-017 to your DC source (0-300V) and the external shunt. Connect the RS485 terminals (A and B) to your USB-to-RS485 adapter. Install Driver: Run the CH340 or CP2102 driver installer. Run Software: Open the PZEM-017 Master software. Configure Port: Select the correct COM Port (found in Device Manager). Set Baud Rate to 9600. Set Modbus Address (Default is 0x01).
Weeks passed. The PZEM-017 sat under a 3D-printed bracket on the wall, its measurements informing decisions: which charger to unplug at night, how to shift dishwasher cycles to solar-rich noon hours. Tom pushed his code back to GitHub with a clear README and a friendly license. He included notes about checksum verification and a suggested adapter. In the repo’s issue tracker, a new user thanked him for the example that had saved them hours of finger-crossing.
I can provide specific instructions, wiring diagrams, or code snippets for your exact setup. AI responses may include mistakes. Learn more Share public link
If your software displays "Time Out," "Communication Error," or zero values, try these fixes:
: Displays live Voltage (V), Current (A), Power (W), and Energy (Wh).