: High-speed counters supporting pulse frequencies up to 100 Hz . To ensure accurate tracking, the signal must respect a minimum duty cycle requirement of 5 milliseconds ON / 5 milliseconds OFF . (Note: Pulse counting is not supported on terminal IN-0) . Network Communications & Protocols
Non-volatile flash memory ensures that both control logic and setup data are preserved during power failures. 2. VLC-1600 Technical Specifications
The controller features high-resolution inputs for accurate monitoring: 16-bit analog/digital universal inputs. Input Types: Accepts thermistor (type II), dry contact, , or dry-contact pulse. Pulse Inputs: Maximum frequency of , with a minimum duty cycle of Sensor Power: Provides max to power external sensors.
Even the best datasheet leaves room for engineering judgment. Here are common omissions:
Field terminations feature removable header-type screw terminals that easily accommodate 14–24 AWG wiring runs. vlc 1600 datasheet
" is also used by some manufacturers for large-scale vertical lathes, the Honeywell/Alerton controller Go to product viewer dialog for this item.
: The upgraded platform features 512 MB of non-volatile flash memory . This safeguards the graphical programming logic and system data against power outages without relying on backup batteries.
Handling numerous points for precise climate control.
The primary design objective of the VLC-1600 series is to expand telemetry dense zones without forcing operators to purchase redundant output circuits. Unlike generic unitary field controllers that split allocations between inputs and outputs (such as the VLC-16160), the VLC-1600 focuses entirely on high-resolution data acquisition. The series exists in two main hardware generations: : High-speed counters supporting pulse frequencies up to
Legacy units operate up to 76.8 Kbps, while modern -E iterations provide hardware auto-baud switching across 9.6, 19.2, 38.4, 76.8, and 115.2 Kbps tiers.
This section defines how the device behaves under normal operation.
: Built-in communication status LEDs provide real-time indicators of TX/RX traffic packets to assist technicians. Programming & Software Integration
: Rated for an expansive environmental range of 0°F to 158°F (-17°C to 70°C) . Input Types: Accepts thermistor (type II), dry contact,
The distinguishing strength of the VLC-1600 series is its . Each of the 16 channels can be independently software-configured to support a variety of signal formats:
: Direct native handling for 3k Ω (Ibex) and 10k Ω (Type II) thermistor temperature elements.
Ideal for AHUs, rooftop units, central plant monitoring, and lighting panel management. 2. VLC-1600 Technical Specifications