Biosystems Bts 350 User | Manual

Biosystems Bts 350 User | Manual

Advanced LED optics improve sensitivity for delicate kinetic assays.

Run a cleaning cycle on the flow cell using dedicated cleaning solutions to prevent carryover.

is a robust and efficient, semi-automated analyzer. By following the detailed procedures outlined in the official user manual, laboratory professionals can ensure precise results and a long lifespan for their equipment. Need the Official Manual?

The BTS 350's functionality relies on a robust optical system. It includes 8 fixed wavelengths (340, 405, 505, 535, 560, 600, 635, 670 nm) with 3 additional spots for optional filters. This advanced design allows for monochromatic and bichromatic readings across a wide measurement range of 0 to 3.5 Abs.

is operated via a LCD graphic display (320x240 pixels) with a user-friendly interface. User Interface Navigation Access Test, Setup, Calibration, and Results. biosystems bts 350 user manual

Keep away from direct sunlight, open windows, and HVAC vents.

The calculated concentration prints automatically upon test completion. 5. Calibration and Quality Control Verification

Ensure the waste line flows downward without kinks to prevent backflow into the flow cell. Operating Modes and Programming

BioSystems BTS-350 is a semi-automatic analyzer designed for clinical chemistry and turbidimetry. It is known for its durable LED-based optical system and low maintenance requirements. Bions Medical Systems Key Features & Capabilities Innovative LED Optical System Advanced LED optics improve sensitivity for delicate kinetic

: A detailed version (Version 1.1, May 2021) covering installation, measurement procedures, and maintenance is available on Scribd .

In the fast-paced world of clinical diagnostics and biochemical analysis, precision is non-negotiable. The is a semi-automatic benchtop analyzer renowned for its reliability in determining clinical parameters in serum, plasma, urine, and other biological fluids. However, even the most sophisticated equipment is only as good as the operator’s understanding of its functions.

: Sets date, time, language, printer options, and calibration curves.

Maintain an ambient operating temperature between 15°C and 32°C. Keep relative humidity below 80% non-condensing. Power Connection By following the detailed procedures outlined in the

Introduce the control or patient sample to the aspiration probe. Press the aspiration trigger switch.

: Aspirate a mild enzymatic cleaner or a 10% bleach solution, let it sit in the flow cell for 5 minutes, and rinse thoroughly with 20 mL of distilled water.

Which (e.g., Enzymes, Substrates) are you trying to program or troubleshoot?

Remove the sample tube immediately when the buzzer alerts you.

Always run a fresh standard or calibrator when switching reagent lots. 4. Routine Maintenance (The "Golden Rules")